POWER R-Line 4B and 4F-ELCT/GNRL/021

Price: on request

  • Pow-R-Line 4B panel board utilizes circuit breakers. Pow-R-Line 4F Panelboards utilizes types FDPW fusible switches.
  • A single chassis accommodates both circuit breakers and fusible switches.
  • Main and neutral are located at the same ends to provide additional space for branch devices.
  • Three-piece trim facilities installations.
  • Will accommodate Series C Circuit Breakers to provide higher ratings in a standard chassis and increased series ratings.
  • UL tested and listed. Meets NEC and NEMA tandards.
  • Pow-R-Line 4B panel board utilizes circuit breakers. Pow-R-Line 4F Panelboards utilizes types FDPW fusible switches.
  • A single chassis accommodates both circuit breakers and fusible switches.
  • Main and neutral are located at the same ends to provide additional space for branch devices.
  • Three-piece trim facilities installations.
  • Will accommodate Series C Circuit Breakers to provide higher ratings in a standard chassis and increased series ratings.
  • UL tested and listed. Meets NEC and NEMA tandards.

General Construction Features

 WESCOSA assembled Panelboards as per Cutler-Hammer technologies are designed for sequence phase connection of branch circuit devices. This allows complete flexibility of circuit arrangement (1-, 2- or 3-poles) to allow balance of the electrical load on each phase.Sturdy rigid chassis assembly assures accurate alignment of interior with panel front; prevents flexing and minimizes possibility of loosening or damage to current carrying parts during and after installation.Four-point in-and-out adjustment of panel interior is provided to meet critical depth dimension on flush installations. This compensates for possible alignment of box at installation. Main lungs are mechanical  solder less type and approved for copper of aluminum conductors.

TECHNICAL DATA

 Table 1: Panelboards Selection Guide

 

 

 

 

 

Panelboard Type

 

 

 

 

 

Device Type

 

Maximum Voltage Rating

 

Maximum Main Rating, Amperes

 

 

Branch Circuit

Ampere Range

Short Circuit Current

Ratings rms Symmetrical Amperes, AC

 

 

AC

 

 

DC

 

Main Lugs Only

 

Main Device

 

Fully Rated (kA)

 

Series Rated (kA)

Pow-R-Line 1a Breaker 240 600 600 15 – 100 10 – 22 22 – 200
Pow-R-Line 2a Breaker 240

480Y/227

250 600

600

600

600

15 – 100

15 – 100

65

14

65 – 200

22 – 150

Pow-R-Line 3a Breaker 240

480

600

250 800

800

800

600

600

600

15 – 225

15 – 225

15 – 225

10 – 200

14 – 100

14 – 35

22 – 200

22 – 150

Pow-R-Line 4b Breaker 240

480

600

250 1200

1200

1200

1200

1200

1200

15 – 1200

15 – 1200

15 – 1200

10 – 200

14 – 200

14 – 200

22 – 200

22 – 150

Pow-R-Line 4f Fusible Switch 240

600

250 1200

1200

1200

1200

30 – 1200

30 – 1200

100 – 200

100 – 200

Table 2: Standard Main Lug Terminals

 

 

Panel Type

Wire Size Ranges for Ampere Capacity
100

Amps

 

225 Amps

 

250 Amps

 

400 Amps

 

600 Amps

 

800 Amps

 

1200 Amps

Pow-R-Line 1a #12–1/0 #6–300 kcmil (2) #2–500 kcmil
Pow-R-Line 2a #12–1/0 #6–300 kcmil (2) #2–500 kcmil
Pow-R-Line 3a #12–1/0 #6 – 350 kcmil (3) #2–500 kcmil (2) #2–500 kcmil (3) #2 – 500 kcmil
Pow-R-Line 4 #2 – 500 kcmil (2) #2–500 kcmil (2) #2–500 kcmil (3) #2 – 500 kcmil (4) #2 – 500 kcmil

 

Breaker Type Ampere Rating Wire Size Ranges
BAB, HQP 15 – 70

90 – 100

#14 – #4

#8 – #1/0

QBHW, QPHW 15 – 70

90 – 100

#14 – #4

#8 – #1/0

ED, EDH, EDC 100 – 225 #4 – #1/0 or #6 – 300 kcmil
EHD, FDB, FD, HFD, FDC 15 – 100

125 – 225

175 – 225

#14 – #1/0

#4 – #4/0

#6 – #350

FCL GHB 15 – 100

15 – 100

#14 – #1/0

#14 – #1/0

GHQ HGHB

GHBS

15 – 20

15 – 30

15 – 30

#14 – #1/0

#14 – #1/0

#14 – #1/0

JD, JDB, HJD, JDC 70 – 250 #4 – 350 kcmil
DK 25 – 350

400

250–500 kcmil

(2) 3/0 – 250 kcmil Or

(1) 3/0 – 500 kcmil

KD, KDB, HKD, KDC, CKD©,

CHKD©

100 – 225

250 – 350

400

(1) #3 – 350 kcmil (1) 250 – 350 kcmil (1) 3/0 – 350 kcmil

(1) 3/0 – 350 kcmil

 

Table 3: Standard Main Breaker, Branch Breaker, Main Switch or Branch Switch Terminals.

 

Breaker Type Ampere Rating Wire Size Ranges
LD, HLD, LDC, 300 – 500 (2) 250 – 350 kcmil
CLD®, 600 (2) 400 – 500 kcmil
CHLD®,    
CLDC®    
MDL, HMDL, 400 – 600 (2) #1 – 500 kcmil
CMDL®, 700 – 800 (3) 3/0 – 400 kcmil
CHMDL®   (2) 500 – 750 kcmil
ND, HND, 600 – 1000 (3) 3/0 – 4000 kcmil
NDC, CND® 1200 (4) 4/0 – 500 kcmil
CHND®    
CNDC®    
LCL 125 – 225 (1) #6 – 350 kcmil
  250 – 400 (1) #4 – 250 kcmil
    And
    (1) 3/0 – 600 kcmil
FB-P 15 –100 #14 – 1/0
LA-P 70 – 225 #6 – 350 kcmil
  250 – 400 (1) #4 – 250 kcmil
    And
    (1) 3/0 – 600 kcmil
NB-P 350 – 700 (2) #1 – 500 kcmil
  800 (3) 3/00 – 400 kcmil
  • 100% rated
  • 100% rated breaker
 

Ampere Rating

 

Wire Size Ranges

30, 60, 100

200

#14 – 1/0

#4 – 300 kcmil

400 250 – 750 kcmil or

(2) 3/0 – 250 kcmil

600 (2) #4 – 600 kcmil or (4) 3/0 – 250 kcmil
800 (3) 250 – 750 kcmil or (6) 3/0 – 250 kcmil
1200 (4) 250 – 750 kcmil or (8) 3/0 – 250 kcmil

 

Table 4: FDPW Switches

 Note: For other terminals available on some ratings of molded case circuit breakers and FDPW fusible switches refer to MCCB CD-ROM and product guide.

Note: All terminal sizes are based on wire ampacities corresponding to those shown in NEC Table 310-16 under 750°C insulation columns (75°C) wire), regardless of insulation temperature is not permitted without voiding UL labels on

 

Reviews

There are no reviews yet.

Be the first to review “POWER R-Line 4B and 4F-ELCT/GNRL/021”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “POWER R-Line 4B and 4F-ELCT/GNRL/021”

Your email address will not be published. Required fields are marked *